Heatpipe Split High Pressure Solar Energy Water Heater
Type | Vertical Pressurized Solar Water Heater Tank |
Capacity | 150L | 200L | 250L | 300L | 400L | 500L | 700L | 1000L |
Inner tank | SUS304 2B δ1.2φ360 | SUS304 2B δ1.5φ450 | SUS304 2B δ1.5φ480 | SUS304 2B δ1.5φ480 | SUS304 2B δ2.0φ580 | SUS304 2B δ2.0φ580 | SUS304 2B δ2.0φ580 | SUS304 2B δ2.5φ800 |
Outer tank | Color Steel δ0.5φ470 | Color Steel δ0.5φ550 | Color Steel δ0.5φ580 | Color Steel δ0.5φ580 | Color Steel δ0.5φ700 | Color Steel δ0.5φ700 | Color Steel δ0.5φ700 | Color Steel δ0.5φ1000 |
PU Foam Insulation | 55mm | 50mm | 50mm | 50mm | 60mm | 60mm | 60mm | 100mm |
Coil heat exchanger | Copper coil φ12/Stainless steel φ15.88/Flexible pipe φ19 |
Working Pressure | Suggest 2bars to 6bars |
P/T Valve | Release when pressure is over 7bars or tempertuare is over 95 °C |
Electric booster | 1.5KW 220V or 2KW 220V normally |
Suitable people | 3persons | 4persons | 5persons | 6persons | 8persons | 10persons | 14persons | 20persons |
Type | CS-HP-10 | CS-HP-15 | CS-HP-20 | CS-HP-25 | CS-HP-30 | CS-HP-15B | CS-HP-30B |
Number of tubes | 10 | 15 | 20 | 25 | 30 | 15 | 30 |
Gross area (m²) | 1.63 | 2.40 | 3.17 | 3.93 | 4.70 | 1.33 | 2.42 |
Aperture area (m²) | 0.94 | 1.41 | 1.88 | 2.35 | 2.82 | 0.63 | 1.30 |
Absorber area (m²) | 0.805 | 1.24 | 1.65 | 2.06 | 2.48 | 0.54 | 1.08 |
Peak power (W / Collector) | 659 | 900 | 1199 | 1499 | 1799 | 450 | 900 |
Allowable operating pressure (bar) | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
Test pressure (bar) | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Max. stagnation temperature | 232°C | 200°C | 200°C | 200°C | 200°C | 200°C | 200°C |
Max. operating temperature | 95°C | 95°C | 95°C | 95°C | 95°C | 95°C | 95°C |
Flow rate (l / m2h) | 50-150 | 50-150 | 50-150 | 50-150 | 50-150 | 50-150 | 50-150 |
Absorber material | CU/AI/SS/N2 Borosilicate glass |
Coating | ALN/SS-ALN/CU |
Absorption coefficient | ≥ 94% | ≥ 94% | ≥ 94% | ≥ 94% | ≥ 94% | ≥ 94% | ≥ 94% |
Emission coefficient | ≤ 7% | ≤ 7% | ≤ 7% | ≤ 7% | ≤ 7% | ≤ 7% | ≤ 7% |
Weight (kg) | 36.4 | 55 | 77 | 96 | 116 | 32 | 65 |
Liquid content | 0.62L | 0.93L | 1.24L | 1.55L | 1.82L | 0.93L | 1.82L |
Mounting angle | 15 - 75° | 15 - 75° | 15 - 75° | 15 - 75° | 15 - 75° | 15 - 75° | 15 - 75° |
Frame | 2mm Aluminum Alloy |
Heat pipe | 8mm red copper |
Long-term stable vacuum (Pa) | <5*10-3 | <5*10-3 | <5*10-3 | <5*10-3 | <5*10-3 | <5*10-3 | <5*10-3 |
Glass tube diameter | 58mm | 58mm | 58mm | 58mm | 58mm | 58mm | 58mm |
Vacuum tube wall thickness | 1.6mm | 1.6mm | 1.6mm | 1.6mm | 1.6mm | 1.6mm | 1.6mm |
Insulation | Compressed Rockwool |
Collector width | 800mm | 1175mm | 1550mm | 1925mm | 2300mm | 1175mm | 2300mm |
Collector length | 2043mm | 1200mm |
Manifold | 38mm red copper |
Tube length | 1800mm | 850mm |
Pressure drop | <5mbar(80L/h), 12mbar (150L/h) |